整体柱反相液相色谱-间接紫外检测法分析四丙基铵根
详细信息    查看全文 | 推荐本文 |
  • 英文篇名:Determination of tetrapropyl ammonium by reversed-phase liquid chromatography-indirect ultraviolet detection using a monolithic column
  • 作者:金鑫鑫 ; 邹春苗 ; 于泓 ; 龚智慧 ; 王刚
  • 英文作者:JIN Xin-xin;ZOU Chun-miao;YU Hong;GONG Zhi-hui;WANG Gang;College of Chemistry and Chemical Engineering,Heilongjiang Key Laboratory of Photochemical Biomaterials and Energy Storage Materials,Harbin Normal University;
  • 关键词:反相液相色谱 ; 间接紫外检测 ; 四丙基铵根离子 ; 咪唑离子液体 ; 整体柱
  • 英文关键词:Reversed-phase liquid chromatography;;Indirect ultraviolet detection;;Tetrapropyl ammonium;;Imidazolium ionic liquid;;Monolithic column
  • 中文刊名:FXSY
  • 英文刊名:Chinese Journal of Analysis Laboratory
  • 机构:哈尔滨师范大学化学化工学院黑龙江省光化学生物材料与储能材料重点实验室;
  • 出版日期:2018-02-01 17:59
  • 出版单位:分析试验室
  • 年:2018
  • 期:v.37
  • 基金:黑龙江省自然科学基金(B201307);; 哈尔滨师范大学创新团队、大学生实践创新基金资助
  • 语种:中文;
  • 页:FXSY201802010
  • 页数:5
  • CN:02
  • ISSN:11-2017/TF
  • 分类号:56-60
摘要
建立了一种反相液相色谱-间接紫外检测分离无紫外光吸收的四丙基铵根离子(TPA)方法。选用反相硅胶整体柱,咪唑类离子液体水溶液/有机溶剂作为淋洗液,研究了背景紫外吸收剂、色谱柱、淋洗液、流速及柱温对分析TPA的影响,并讨论了保留规律。设定检测波长210 nm,柱温30℃,流速1.0 mL/min,0.7 mmol/L[EM IM][BF4]水溶液(通过乙酸调节pH 4.5)/甲醇(80/20,V/V)作为淋洗液,TPA的保留时间2.11 min,检出限0.78 mg/L,峰面积的相对标准偏差(RSD)0.70%,保留时间的RSD为0.030%。方法用于检测实验室合成的溴化四丙基铵离子液体样品,加标回收率99.2%。
        A reversed-phase liquid chromatography-indirect ultraviolet detection method was developed for the determination of tetrapropyl ammionium(TPA) that have no ultraviolet absorption.The reversed phase silica gel monolithic column and eluent of imidazolium ionic liquid aqueous solution/organic solvent were used.The effects of background UV absorber,column,eluent,flow rate and column temperature on the determination of TPA were investigated and the retention rules were discussed.The instrumental parameters were set as follows:detection wavelength:210 nm,column temperature:30℃,flow rate:1 mL/min.0.7 mmol/L 1-ethyl-3-methylimidazolium tetrafluoroborate solution(pH 4.5 adjusted by acetic acid)/methanol(80/20,V/V) was used as eluent.The retention time of TPA was 2.11 min,with the detection limit of 0.78 mg/L,and the relative standard deviation(RSD) of peak area and retention time were 0.70% and 0.030%,respectively.In this way,laboratory synthetic ion liquid samples of four propyl ammonium bromide were determined with a recovery rate of 99.2%.This method is efficient and practical.
引文
[1]Geng R Y,Lv X C,Li G K,et al.Res.Environ.Sci.,2016,29(3):427耿仁勇,吕雪川,李国轲,等.环境科学研究,2016,29(3):427
    [2]Zhang W,Dai X L,Zhou J J,et al.Fibers and Polymers.,2017,18(2):290
    [3]Lu S,Ji R.Industrial Water Treatment.,2011,31(9):76卢姝,纪然.工业水处理,2011,31(9):76
    [4]Liu Y Q,Chen Q,Yu H,et al.J.Instrum.Anal.,2014,33(10):1154刘永强,陈倩,于泓,等.分析测试学报,2014,33(10):1154
    [5]Xie N,Leng T H,Chen G Y,et al.Chin.J.Anal.Lab.,2015,34(2):222解楠,冷桃花,陈贵宇,等.分析试验室,2015,34(2):222
    [6]Tian Q P,Li W Y,Xie K C.Chin.J.Anal.Lab.,2009,28(2):21田青平,李文英,谢克昌.分析试验室,2009,28(2):21
    [7]Daghir W E,Studzinska S,Buszewski B,et al.Anal.Methods.,2014,6(4):1189
    [8]Felicia P H,Yu H.Anal.Lett.,2016,49(8):1154
    [9]Ying L Y,Jiang H L,Zhou S C,et al.Chin.J.Anal.Lab.,2017,36(1):56应丽艳,江海亮,周赛春,等.分析试验室,2017,36(1):56
    [10]Liu J X,Chen Y H,Feng S H,et al.Chin.J.Anal.Lab.,2017,36(5):534刘进玺,陈颖慧,冯书惠,等.分析试验室,2017,36(5):534
    [11]Ai H J,Chen Q,Yu H.Chin.J.Anal.Lab.,2011,30(11):65艾红晶,陈倩,于泓.分析试验室,2011,30(11):65
    [12]Li R Z,Yu H,Gao W,et al.Chin.J.Anal.Lab.,2010,29(3):85李睿姝,于泓,高微,等.分析试验室,2010,29(3):85
    [13]Sun Y M,Yu H.Chin.J.Chromatogr.,2013,31(10):969孙艺梦,于泓.色谱,2013,31(10):969
    [14]Yu H,Sun Y M,Zou C M.Chin.Chem.Lett.,2014,25(10):1371
    [15]Wang M Y,Sun Y M,Yu H,et al.Chem.Res.App.,2015,27(9):1343王淼煜,孙艺梦,于泓,等.化学研究与应用,2015,27(9):1343
    [16]Zhao D,Yu H.J.Instrum.Anal.,2017,36(1):112赵丹,于泓.分析测试学报,2017,36(1):112
    [17]Zhang X D,Bu W,Liu F,et al.Chem.Res.App.,2016,28(7):1020张小东,卜文,刘峰,等.化学研究与应用,2016,28(7):1020